300/500 V 70°C VAF-G
2 Cores - Pvc Insulated And Sheathed Cable, Flat Type With Ground
Application
Use for surface wiring
For installation in raceway
Do not install in conduit
Do not burial in ground
Construction
Conductor:Solid or circular stranded annealed copper
Insulation:Polyvinyl chloride (PVC).Phase - Light Blue, Brown,Ground - Green/Yellow
Sheath :Polyvinyl chloride (PVC), White colour
Reference Standard
TIS 11 Part 101-2553
Technical Characteristics
Maximum conductor temperature : 70°C
Rated voltage : 300/500 V
AC test voltage : 2,000 V
Conductor | Thickness of insulation | Thickness of sheath | Overall diameter | Insulation resistance at 70 °C (Min.) | Current rating on wall | Cable weight (Approx.) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cross-sectional area | No. of wires (Min.) | Diameter (Approx.) | |||||||||||
Lower limit | Upper limit | ||||||||||||
Phase | Ground | Phase | Ground | Phase | Ground | Phase | Ground | ||||||
mm2 | mm2 | mm2 | mm | mm | mm | mm | mm | mm | mm | km | A | kg/km | |
1 | 1 | 1 | 1 | 1.11 | 1.11 | 0.6 | 0.6 | 0.9 | 4.0x8.4 | 4.7x9.8 | 0.0110 | 14 | 74 |
1.5 | 1.5 | 1 | 1 | 1.36 | 1.36 | 0.7 | 0.7 | 0.9 | 4.4x9.8 | 5.4x11.5 | 0.0110 | 17 | 100 |
2.5 | 2.5 | 1 | 1 | 1.75 | 1.75 | 0.8 | 0.8 | 1.0 | 5.2x11.5 | 6.2x13.5 | 0.0100 | 23 | 150 |
4 | 4 | 7 | 7 | 2.49 | 2.49 | 0.8 | 0.8 | 1.1 | 5.8x13.4 | 7.4x16.5 | 0.0077 | 32 | 230 |
6 | 6 | 7 | 7 | 3.09 | 3.09 | 0.8 | 0.8 | 1.1 | 6.4x15.0 | 8.0x18.0 | 0.0065 | 41 | 300 |
10 | 10 | 7 | 7 | 3.99 | 3.99 | 1.0 | 1.0 | 1.2 | 7.8x19.0 | 9.6x22.5 | 0.0065 | 56 | 490 |
16 | 16 | 7 | 7 | 5.01 | 5.01 | 1.0 | 1.0 | 1.3 | 9.0x22.0 | 11.0x26.5 | 0.0052 | 74 | 710 |